• DocumentCode
    847969
  • Title

    Fast and accurate switching transient calculations on transmission lines with ground return using recursive convolutions

  • Author

    Semlyen, A. ; Dabuleanu, A.

  • Author_Institution
    University of Toronto, Toronto, Ontario, Canada
  • Volume
    94
  • Issue
    2
  • fYear
    1975
  • fDate
    3/1/1975 12:00:00 AM
  • Firstpage
    561
  • Lastpage
    571
  • Abstract
    The paper presents a new approach to the calculation of transients on transmission lines with frequency-dependent parameters. Its purpose is to obtain significant computer-time savings by avoiding convolutions. This is achieved by approximating all line and ground distortions and also time variable characteristic admittances by exponential functions, i.e. solutions of linear differential equations. The method produces a simple Norton-type line equivalent which permits its incorporation into an existing system representation like the B.P.A. program for the calculation of transients. The program has been tested on systems of different degrees of complexity and proved to be superior, in terms of speed and accuracy, to other advanced methods.
  • Keywords
    Circuits; Differential equations; Frequency dependence; Frequency domain analysis; Power system transients; Surges; System testing; Time measurement; Transfer functions; Transmission lines;
  • fLanguage
    English
  • Journal_Title
    Power Apparatus and Systems, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9510
  • Type

    jour

  • DOI
    10.1109/T-PAS.1975.31884
  • Filename
    1601486