Title :
Enhanced Hot Spot Cooling Using Bonded Superlattice Microcoolers With a Trench Structure
Author :
Zhang, Yan ; Zeng, Gehong ; Hoffman, Christine ; Bar-Cohen, Avram ; Shakouri, Ali
Author_Institution :
Tessera, Inc., San Jose, CA
Abstract :
In this paper, we describe how to use Si/SiGe superlattice microcoolers to cool the target hot spots and how a trench structure could enhance its cooling performance. The microcooler chip is gold fusion bonded with a 65 mum-thick silicon chip, where heaters are fabricated on the opposite of fusion bonding layer to simulate the hot spots. Our 3-D electrothermal simulations showed that with a trench structure, the maximum cooling and cooling power density could be doubled at hot spot region. Our experimental prototype also demonstrated a maximum cooling of ~ 2degC reduction at hot spot or a maximum cooling power density of 110 W/cm with trench structure as compared with the 0.8degC cooling without trench structure. This two-chip bonded configuration will allow the integration of spot coolers and ICs without impact on microelectronics processing process. It could be a potential on-chip hot spot cooling solution.
Keywords :
Ge-Si alloys; bonding processes; cooling; integrated circuits; semiconductor materials; semiconductor superlattices; 3D electrothermal simulations; IC; Si-SiGe; bonded superlattice microcoolers; cooling power density; fusion bonded; fusion bonding layer; maximum cooling; microcooler chip; on-chip hot spot cooling solution; silicon chip; trench structure; two-chip bonded configuration; Cooling; hot spot; microrefrigerator; trench;
Journal_Title :
Components and Packaging Technologies, IEEE Transactions on
DOI :
10.1109/TCAPT.2008.2001833