Title :
Bio-Assessing of Environmental Pollution via Monitoring of Metallothionein Level Using Electrochemical Detection
Author :
Stejskal, Karel ; Krizkova, Sona ; Adam, Vojtech ; Sures, Bernd ; Trnkova, Libuse ; Zehnalek, Josef ; Hubalek, Jaromir ; Beklova, Miroslava ; Hanustiak, Pavel ; Svobodova, Zdenka ; Horna, Ales ; Kizek, Rene
Author_Institution :
Dept. of Chem. & Biochem., Mendel Univ. of Agric. & Forestry, Brno
Abstract :
In this paper, we report on an investigation of affecting guppy fishes (Poecilia reticulata) by silver ions (0, 0.3, 0.6, 1.2, 2.5, and 5 muM) for seven days under well-controlled experimental conditions. To observe the physiological changes, we attempted to determine metallothionein (MT) as a biomarker of heavy metal stress. For this purpose, we proposed a sensor utilizing a carbon electrode coupled with flow injection analysis. The experimental conditions, which have been optimized, were as follows-applied potential: 750 mV, mobile phase: Britton-Robinson buffer (pH 1.9) with flow rate of 0.6 ml/min, time filter: 2.5 s, "current R": 1 muA. Under these conditions, the detection limit of MT was estimated as 100 pM. After the optimizing step, the fish tissues were measured. Based on the results obtained, MT content increased with increasing dose of silver ions and time of the treatment. The results obtained were in good correlation with those obtained by adsorptive transfer stripping technique coupled with differential pulse voltammetry Brdicka reaction, which was used as the reference technique.
Keywords :
amperometric sensors; biochemistry; biological techniques; biological tissues; carbon; electrochemical electrodes; molecular biophysics; pollution measurement; proteins; silver; water pollution; zoology; Ag+; Britton-Robinson buffer; C; Poecilia reticulata; adsorptive transfer stripping technique; amperometric detection; bio-assessment; carbon electrode; differential pulse voltammetry Brdicka reaction; electrochemical detection; electrochemical sensors; environmental pollution; fish tissues measurements; flow injection analysis; guppy fishes; heavy metal stress biomarker; metallothionein level monitoring; mobile phase; physiological changes; silver ions; voltage 750 mV; Biomarkers; Biomedical monitoring; Biosensors; Carbon dioxide; Electrodes; Filters; Marine animals; Pollution; Silver; Stress; Amperometric detection; biomarker; electrochemical sensors; fish; flow injection analysis; heavy metal; metallothionein; poecilia reticulata; silver;
Journal_Title :
Sensors Journal, IEEE
DOI :
10.1109/JSEN.2008.928500