DocumentCode :
849771
Title :
Bayesian Calibration of a Lookup Table for ADC Error Correction
Author :
De Vito, Luca ; Lundin, Henrik ; Rapuano, Sergio
Author_Institution :
Dept. of Eng., Univ. of Sannio, Benevento
Volume :
56
Issue :
3
fYear :
2007
fDate :
6/1/2007 12:00:00 AM
Firstpage :
873
Lastpage :
878
Abstract :
This paper presents a new method for the correction of nonlinearity errors in analog-to-digital converters (ADCs). The method has been designed to allow a self-calibration in systems where an internal signal can be generated, such as base stations for mobile communications. The method has been implemented and tested in simulation on the behavioral model of commercial ADCs and on a hardware setup composed by a data acquisition board and a distorting circuit
Keywords :
Bayes methods; analogue-digital conversion; calibration; data acquisition; error correction; mobile communication; table lookup; ADC error correction; Bayesian calibration; analog-to-digital converters; data acquisition board; lookup table; mobile communications; nonlinearity errors; self-calibration; Analog-digital conversion; Base stations; Bayesian methods; Calibration; Circuit testing; Design methodology; Error correction; Signal design; Signal generators; Table lookup; Analog-to-digital converters (ADCs); Bayes theorem; correction; lookup table (LUT);