DocumentCode
850588
Title
AC behaviour of full size, fusion dedicated cable-in-conduit conductors in SULTAN III under applied pulsed field
Author
Blau, B. ; Rohleder, I. ; Vecsey, G. ; Bottura, L. ; Bruzzone, P. ; Katheder, H.
Author_Institution
The NET Team, Max-Planck-Inst. fur Plasmaphys., Garching bei Munchen, Germany
Volume
5
Issue
2
fYear
1995
fDate
6/1/1995 12:00:00 AM
Firstpage
697
Lastpage
700
Abstract
The coupling current losses of a full size, fusion dedicated Nb/sub 3/Sn cable-in-conduit superconductor are measured as a function of the transverse load in the SULTAN III test facility. Applying a broad range of transport current (up to 56 kA) and background field (up to 12.1 T), the change of the transverse resistance is observed through the shift of the O-crossing in the pick-up coil voltage. Despite the difficulty to extract useful information from the signal, the role of the strand Cr plating as resistive barrier is experimentally assessed under operating conditions. The friction factor of the conductor is also evaluated from pressure drop measurements.<>
Keywords
electric conduits; loss measurement; losses; power cable testing; power cables; pressure measurement; superconducting cables; superconducting magnets; voltage measurement; 12.1 T; 56 kA; AC loss tests; Cr; Nb/sub 3/Sn; O-crossing; SULTAN III test facility; background field; cable-in-conduit superconductors; coupling current losses; friction factor; pick-up coil voltage; pressure drop measurements; resistive barrier; strand Cr plating; superconducting magnet; transport current; transverse load; transverse resistance; Coils; Conductors; Current measurement; Electrical resistance measurement; Loss measurement; Niobium; Size measurement; Superconducting cables; Test facilities; Tin;
fLanguage
English
Journal_Title
Applied Superconductivity, IEEE Transactions on
Publisher
ieee
ISSN
1051-8223
Type
jour
DOI
10.1109/77.402643
Filename
402643
Link To Document