• DocumentCode
    850601
  • Title

    A Laboratory Experimental Technique for Determining Satellite Cable Response to SGEMP

  • Author

    Chadsey, W.L. ; Tigner, J.E. ; Miller, R.I. ; Smith, P.

  • Author_Institution
    Technological Systems Group Science Applications, Inc. 8330 Old Courthouse Road, Suite 510 Vienna, Virginia 22180
  • Volume
    27
  • Issue
    6
  • fYear
    1980
  • Firstpage
    1547
  • Lastpage
    1551
  • Abstract
    An experimental technique has been developed which uses a continuous, low-level, X-ray source to determine the direct drive SGEMP response of satellite cables. Preliminary experimental results are presented for three types of cables. The direct drive responses obtained in the continuous X-ray experiments are compared with responses obtained in flash X-ray and underground test experiments.
  • Keywords
    Cable shielding; Communication cables; Drives; Laboratories; Power cables; Predictive models; Pulse generation; Satellites; Testing; Uncertainty;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/TNS.1980.4331067
  • Filename
    4331067