DocumentCode
850601
Title
A Laboratory Experimental Technique for Determining Satellite Cable Response to SGEMP
Author
Chadsey, W.L. ; Tigner, J.E. ; Miller, R.I. ; Smith, P.
Author_Institution
Technological Systems Group Science Applications, Inc. 8330 Old Courthouse Road, Suite 510 Vienna, Virginia 22180
Volume
27
Issue
6
fYear
1980
Firstpage
1547
Lastpage
1551
Abstract
An experimental technique has been developed which uses a continuous, low-level, X-ray source to determine the direct drive SGEMP response of satellite cables. Preliminary experimental results are presented for three types of cables. The direct drive responses obtained in the continuous X-ray experiments are compared with responses obtained in flash X-ray and underground test experiments.
Keywords
Cable shielding; Communication cables; Drives; Laboratories; Power cables; Predictive models; Pulse generation; Satellites; Testing; Uncertainty;