DocumentCode :
851515
Title :
Parameter identification and verification of low order boiler models
Author :
Herget, Charles J. ; Park, Chan U.
Author_Institution :
Iowa State University, Ames, Iowa
Volume :
95
Issue :
4
fYear :
1976
fDate :
7/1/1976 12:00:00 AM
Firstpage :
1153
Lastpage :
1158
Abstract :
The results of studies performed for the verification and parameter identification of a low-rder boiler model from actual operating data are presented. The model chosen for identification and verification is a linear fourth order system with eight unknown parameters and two inputs and two outputs. The model is intended for use in stability studies over the time interval of approximately one-half minute to a few minutes following a disturbance.
Keywords :
Boilers; Mathematical model; Parameter estimation; Power generation; Power system dynamics; Power system interconnection; Power system modeling; Power system simulation; Power system stability; Testing;
fLanguage :
English
Journal_Title :
Power Apparatus and Systems, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9510
Type :
jour
DOI :
10.1109/T-PAS.1976.32208