High rate spectroscopy for on-line nuclear coal analyzer (nucoalyzerTM conac)
Author
McQuaid, J.H. ; Brown, D.R. ; Gozani, T. ; Bozorgmanesh, H.
Author_Institution
Lawrence Livermore National Laboratory
Volume
28
Issue
1
fYear
1981
Firstpage
304
Lastpage
307
Abstract
A high count rate, time-variant Ge(Li) spectrometer has been developed for on-line coal analysis. The analyzer is being fabricated for use in a power generating station. Prompt neutron activation of coal samples is the basis of analysis, with 252Cf as the source for irradiation. The spectroscopy system allows counting rates up to 150 k counts per second without significant loss in energy resolution or peak shape. The high data throughput allows the coal analyzer to be used for on-line process control. The coal analyzer will be discussed, with emphasis on the high-rate signal processing system. Results of analysis of coal samples will be presented.
Keywords
Activation analysis; Control system analysis; Energy resolution; Neutrons; Nuclear power generation; Power generation; Process control; Shape; Spectroscopy; Throughput;