• DocumentCode
    852225
  • Title

    Gas-Ionization Sampling Calorimeters

  • Author

    Atac, M.

  • Author_Institution
    Fermi National Accelerator Laboratory Batavia, IL 60510
  • Volume
    28
  • Issue
    1
  • fYear
    1981
  • Firstpage
    492
  • Lastpage
    495
  • Abstract
    Main features of gas-ionization sampling calorimeters are outlined and compared with acrylic scintillator wave-length shifter calorimeters. Calorimetry by track counting using Geiger and limited streamer modes is discussed.
  • Keywords
    Calibration; Calorimetry; Cathodes; Energy resolution; Ion accelerators; Ionization; Iron; Sampling methods; Solid scintillation detectors; Wires;