• DocumentCode
    852409
  • Title

    Combined natural and forced convective cooling of underground eletric cables

  • Author

    Abdulhadi, Rami S. ; Chato, John C.

  • Author_Institution
    University of Illinois at Urbana-Champaign, Urbana, Illinois
  • Volume
    96
  • Issue
    1
  • fYear
    1977
  • Firstpage
    1
  • Lastpage
    8
  • Abstract
    Experimental results have been obtained for a wide range of physical, flow, and thermal parameters in three models of underground electric cable systems. The results show that the laminar friction factors depend on cable configuration and have an upper limit of f ċ Re = 30. Laminar Nusselt numbers are independent of the skid wire roughness ratio and the Reynolds number but increase with increasing Rayleigh numbers and axial distance from the inlet. The range of laminar Nusselt numbers was 6 to 18. In the turbulent region, both the friction factors and Nusselt numbers are increasing functions of the skid wire roughness ratio. For roughness ratios of 0.0216 and 0.0293, the asymptotic friction factor values were 0.013 and 0.021, respectively. The Nusselt numbers at Re = 3,000 are about 40 and 60 for the above roughness ratios.
  • Keywords
    Cable insulation; Conductors; Cooling; Friction; Heat transfer; Hydraulic diameter; Petroleum; Resistance heating; Temperature; Underground power cables;
  • fLanguage
    English
  • Journal_Title
    Power Apparatus and Systems, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9510
  • Type

    jour

  • DOI
    10.1109/T-PAS.1977.32298
  • Filename