DocumentCode :
852661
Title :
The Development and Use of a Travelling Flux Detector System for Candu Reactors
Author :
Allan, C.J. ; McDonald, A.M. ; Cuttler, J.M. ; Erven, J.H.
Author_Institution :
Atomic Energy of Canada Ltd. Research Company Chalk River Nuclear Laboratories Chalk River, Ontario K0J 1J0
Volume :
28
Issue :
1
fYear :
1981
Firstpage :
719
Lastpage :
727
Abstract :
A portable Travelling Flux Detector (TFD) system has been developed for use on the NRU research reactor at Chalk River, as a first step in developing a TFD system for use on CANDU reactors. The NRU system uses a miniature fission chamber moved by a Babcock and Wilcox drive frame. Results obtained from NRU and from the Bruce Nuclear Generating Station A (NGS A), using a TFD, are presented and discussed. Potential applications of such a system on CANDU power reactors include (i) in-situ calibration of fixed incore detectors, (ii) measurement of creep-sag of fuel channels, (iii) measurement of flux profiles during commissioning, for comparison with physics codes, and (iv) investigation of apparent detector failures and/ or flux anomalies.
Keywords :
Assembly systems; Calibration; Detectors; Fuels; Inductors; Laboratories; Nuclear power generation; Power engineering and energy; Power measurement; Rivers;
fLanguage :
English
Journal_Title :
Nuclear Science, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9499
Type :
jour
DOI :
10.1109/TNS.1981.4331268
Filename :
4331268
Link To Document :
بازگشت