Title :
The VICKSI Accelerator Facility and Its Application to Measurements of Charge Exchange Losses
Author :
Becchetti, F. ; Chao, Ch.-W. ; Martin, B. ; Michaelsen, R. ; Spellmeyer, B. ; Ziegler, K.
Author_Institution :
Hahn-Meitner-Institut fÿr Kernforschung Berlin GmbH, Bereich Kern-und Strahlenphysik, Berlin, Germany
fDate :
4/1/1981 12:00:00 AM
Abstract :
A description of the VICKSI facility is given with emphasis on the special properties which make VICKSI particularly suitable for measurements of charge exchange losses during cyclotron acceleration. Measurements of these losses for carbon-, neon- and argon-ions at different vacuum levels are reported. At the normal operating pressure of VICKSI, namely 3 . 10-7 mbar, no losses could be observed for carbon and neon ions, while for argon the transmission to extraction radius was 92%.
Keywords :
Acceleration; Accelerometers; Chaos; Charge measurement; Current measurement; Cyclotrons; Ion accelerators; Loss measurement; Optical losses; Particle beams;
Journal_Title :
Nuclear Science, IEEE Transactions on
DOI :
10.1109/TNS.1981.4331436