DocumentCode :
854559
Title :
The effect of third harmonic flux distortion on the core losses in thin magnetic steel laminations
Author :
Lavers, J.D. ; Biringer, P.P. ; Hollitscher, H.
Author_Institution :
University of Toronto, Toronto, Canada
Volume :
96
Issue :
6
fYear :
1977
Firstpage :
1856
Lastpage :
1862
Abstract :
A simple and practical method of estimating the effect of 3rd harmonic flux distortion on the total core loss in a thin lamination is described. The necessary eddy current correction factor is derived using simple methods. For distortion levels of less than 30%, it is shown that the hysteresis loss remains unchanged from its sinusoidal value, to a good approximation. Experimentally measured losses in 0.014" and 0.025" laminations, at distorted flux levels ranging from 0.8 to 1.9 T, are used to verify the results of the analysis.
Keywords :
Core loss; Distortion measurement; Eddy currents; Harmonic distortion; Lamination; Loss measurement; Magnetic flux; Reliability theory; Saturation magnetization; Steel;
fLanguage :
English
Journal_Title :
Power Apparatus and Systems, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9510
Type :
jour
DOI :
10.1109/T-PAS.1977.32519
Filename :
1602121
Link To Document :