DocumentCode
854559
Title
The effect of third harmonic flux distortion on the core losses in thin magnetic steel laminations
Author
Lavers, J.D. ; Biringer, P.P. ; Hollitscher, H.
Author_Institution
University of Toronto, Toronto, Canada
Volume
96
Issue
6
fYear
1977
Firstpage
1856
Lastpage
1862
Abstract
A simple and practical method of estimating the effect of 3rd harmonic flux distortion on the total core loss in a thin lamination is described. The necessary eddy current correction factor is derived using simple methods. For distortion levels of less than 30%, it is shown that the hysteresis loss remains unchanged from its sinusoidal value, to a good approximation. Experimentally measured losses in 0.014" and 0.025" laminations, at distorted flux levels ranging from 0.8 to 1.9 T, are used to verify the results of the analysis.
Keywords
Core loss; Distortion measurement; Eddy currents; Harmonic distortion; Lamination; Loss measurement; Magnetic flux; Reliability theory; Saturation magnetization; Steel;
fLanguage
English
Journal_Title
Power Apparatus and Systems, IEEE Transactions on
Publisher
ieee
ISSN
0018-9510
Type
jour
DOI
10.1109/T-PAS.1977.32519
Filename
1602121