• DocumentCode
    855640
  • Title

    Calibration of energy and power meters under non-sinusoidal conditions

  • Author

    Georgakopoulos, D. ; Wright, P.S.

  • Author_Institution
    Nat. Phys. Lab., Teddington
  • Volume
    153
  • Issue
    6
  • fYear
    2006
  • fDate
    11/1/2006 12:00:00 AM
  • Firstpage
    241
  • Lastpage
    247
  • Abstract
    Power systems contain distorted voltage and current waveforms. Currently, there is not a preferred set of voltage and current waveforms for the calibration of power and energy meters under non-sinusoidal conditions. The paper concentrates on the calibration of power and energy meters under sinusoidal and non-sinusoidal conditions. In particular, criteria for selecting voltage and current waveforms, a calibration procedure and a set of voltage and current waveforms for the calibration of power and energy meters under non-sinusoidal conditions are proposed
  • Keywords
    calibration; harmonic distortion; power meters; power system harmonics; power system measurement; distorted current waveforms; distorted voltage waveforms; energy meters; nonsinusoidal conditions; power meters; power system;
  • fLanguage
    English
  • Journal_Title
    Science, Measurement and Technology, IEE Proceedings -
  • Publisher
    iet
  • ISSN
    1350-2344
  • Type

    jour

  • DOI
    10.1049/ip-smt:20050098
  • Filename
    4027843