DocumentCode :
855640
Title :
Calibration of energy and power meters under non-sinusoidal conditions
Author :
Georgakopoulos, D. ; Wright, P.S.
Author_Institution :
Nat. Phys. Lab., Teddington
Volume :
153
Issue :
6
fYear :
2006
fDate :
11/1/2006 12:00:00 AM
Firstpage :
241
Lastpage :
247
Abstract :
Power systems contain distorted voltage and current waveforms. Currently, there is not a preferred set of voltage and current waveforms for the calibration of power and energy meters under non-sinusoidal conditions. The paper concentrates on the calibration of power and energy meters under sinusoidal and non-sinusoidal conditions. In particular, criteria for selecting voltage and current waveforms, a calibration procedure and a set of voltage and current waveforms for the calibration of power and energy meters under non-sinusoidal conditions are proposed
Keywords :
calibration; harmonic distortion; power meters; power system harmonics; power system measurement; distorted current waveforms; distorted voltage waveforms; energy meters; nonsinusoidal conditions; power meters; power system;
fLanguage :
English
Journal_Title :
Science, Measurement and Technology, IEE Proceedings -
Publisher :
iet
ISSN :
1350-2344
Type :
jour
DOI :
10.1049/ip-smt:20050098
Filename :
4027843
Link To Document :
بازگشت