DocumentCode :
856604
Title :
Four-Dimensional Beam Tomography
Author :
Minerbo, G.N. ; Sander, O.R. ; Jameson, R.A.
Author_Institution :
Los Alamos National Laboratory, Los Alamos, NM 87545
Volume :
28
Issue :
3
fYear :
1981
fDate :
6/1/1981 12:00:00 AM
Firstpage :
2231
Lastpage :
2233
Abstract :
A computer code has been developed to reconstruct the 4-D transverse phase-space distribution of an accelerator beam from a set of linear profiles measured at different angles at three or more stations along the beam line. The code was applied to wirescan data obtained on the low-intensity H- beam of the LAMPF accelerator. A 4-D reconstruction was obtained from 10 wire-scan profiles; 2-D projections of the reconstruction agree fairly well with slit-and-collector measurements of the horizontal and vertical emittance distributions.
Keywords :
Covariance matrix; Distributed computing; Entropy; Goniometers; Laboratories; Particle beams; Phase measurement; Stimulated emission; Tomography; Wire;
fLanguage :
English
Journal_Title :
Nuclear Science, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9499
Type :
jour
DOI :
10.1109/TNS.1981.4331646
Filename :
4331646