Title :
Large Barkhausen effect of 6.3% SiFe single crystal wire
Author :
Mohri, K. ; Takamido, H.
Author_Institution :
Dept. of Electr. Eng., Nagoya Unvi., Japan
fDate :
9/1/1990 12:00:00 AM
Abstract :
A sensitive and stable large Barkhausen effect was observed for 4-8% SiFe single-crystal wires. New pulse generator elements were constructed using 6.3% SiFe single-crystal wire which has nearly zero magnetostriction (λ100). Pulse voltage were induced at a pickup coil for an applied AC field of more than about 0.2 Oe with frequencies of 0.01 Hz to 10 kHz. The high reliability of pulse generation characteristics against disturbance stresses was estimated for the 6.3% SiFe single-crystal wire. A reliable and accurate magnetic-field sensor developed on the basis of the proposed technique is described
Keywords :
Barkhausen effect; ferromagnetic properties of substances; iron alloys; magnetic field measurement; nonelectric sensing devices; silicon alloys; Barkhausen effect; SiFe; applied AC field; disturbance stresses; magnetic-field sensor; pickup coil; pulse generation characteristics; pulse generator elements; single crystal wire; Amorphous materials; Coils; Frequency estimation; Magnetic anisotropy; Magnetic field measurement; Magnetostriction; Pulse generation; Pulse measurements; Voltage; Wires;
Journal_Title :
Magnetics, IEEE Transactions on