DocumentCode :
857132
Title :
Large Barkhausen effect of 6.3% SiFe single crystal wire
Author :
Mohri, K. ; Takamido, H.
Author_Institution :
Dept. of Electr. Eng., Nagoya Unvi., Japan
Volume :
26
Issue :
5
fYear :
1990
fDate :
9/1/1990 12:00:00 AM
Firstpage :
1783
Lastpage :
1785
Abstract :
A sensitive and stable large Barkhausen effect was observed for 4-8% SiFe single-crystal wires. New pulse generator elements were constructed using 6.3% SiFe single-crystal wire which has nearly zero magnetostriction (λ100). Pulse voltage were induced at a pickup coil for an applied AC field of more than about 0.2 Oe with frequencies of 0.01 Hz to 10 kHz. The high reliability of pulse generation characteristics against disturbance stresses was estimated for the 6.3% SiFe single-crystal wire. A reliable and accurate magnetic-field sensor developed on the basis of the proposed technique is described
Keywords :
Barkhausen effect; ferromagnetic properties of substances; iron alloys; magnetic field measurement; nonelectric sensing devices; silicon alloys; Barkhausen effect; SiFe; applied AC field; disturbance stresses; magnetic-field sensor; pickup coil; pulse generation characteristics; pulse generator elements; single crystal wire; Amorphous materials; Coils; Frequency estimation; Magnetic anisotropy; Magnetic field measurement; Magnetostriction; Pulse generation; Pulse measurements; Voltage; Wires;
fLanguage :
English
Journal_Title :
Magnetics, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9464
Type :
jour
DOI :
10.1109/20.104524
Filename :
104524
Link To Document :
بازگشت