Abstract :
The injector for the Fusion Materials Irradiation Test (FMIT) Facility must deliver a 110-mA dc beam of deuterons or H2+ ions to the radio-frequency quadrupole (RFQ) accelerator at 75-keV energy. Operational parameters of a hydrogen-fed cusp-field ion source and a high-perveance extractor have been evaluated on a test stand and on the recently completed first stage of the prototype injector (Fig. 1).
Keywords :
Current density; Electrodes; Electron beams; Geometry; Ion accelerators; Ion sources; Magnets; Optimization; Particle beams; Testing;