• DocumentCode
    858479
  • Title

    Data-Acquisition System for the Fast Criticals ZPR-6 and ZPR-9

  • Author

    Cohn, Charles E.

  • Author_Institution
    Applied Physics Division Argonne National Laboratory Argonne, Illinois 60439
  • Volume
    28
  • Issue
    5
  • fYear
    1981
  • Firstpage
    3680
  • Lastpage
    3683
  • Abstract
    This system is used for experimental data acquisition and processing for the ZPR-6 and ZPR-9 fast critical assemblies. It replaces a setup based on a Systems SEL-840 computer that had been in use for almost a decade. It is noteworthy for a number of departures from standard Harris hardware and software. These were made to minimize expense and to facilitate this changeover as well as future changeovers.
  • Keywords
    Assembly systems; CAMAC; Data acquisition; Drives; Floating-point arithmetic; Hardware; Laboratories; Magnetic heads; Physics; Software standards;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/TNS.1981.4331829
  • Filename
    4331829