• DocumentCode
    859697
  • Title

    Design and Performance of the 1.5 MV Injector for FXR

  • Author

    Kulke, Bernhard ; Ravenscroft, D.S. ; Vogtl, G.E.

  • Author_Institution
    Lawrence Livermore National Laboratory Livermore, California 94550
  • Volume
    28
  • Issue
    3
  • fYear
    1981
  • fDate
    6/1/1981 12:00:00 AM
  • Firstpage
    2882
  • Lastpage
    2884
  • Abstract
    The new flash x-ray machine (FXR) at LLNL is scheduled for completion in late 1981. This is a 54 module, linear induction accelerator, designed to deliver 500 Roentgen at 1 m as bremsstrahlung from a 20 MeV, 4 kA, 60 ns pulsed electron beam. The 1.5 MV, cold cathode injector makes use of six accelerator modules as voltage sources. High voltage testing of the accelerator modules and their associated pulse forming lines and Marx banks has been completed, and beam tests of the complete injector assembly are in progress. Design information and preliminary test results are presented.
  • Keywords
    Anodes; Assembly; Cathodes; Collimators; Diodes; Impedance; Laboratories; Structural beams; Testing; Voltage;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/TNS.1981.4331946
  • Filename
    4331946