Abstract :
The new flash x-ray machine (FXR) at LLNL is scheduled for completion in late 1981. This is a 54 module, linear induction accelerator, designed to deliver 500 Roentgen at 1 m as bremsstrahlung from a 20 MeV, 4 kA, 60 ns pulsed electron beam. The 1.5 MV, cold cathode injector makes use of six accelerator modules as voltage sources. High voltage testing of the accelerator modules and their associated pulse forming lines and Marx banks has been completed, and beam tests of the complete injector assembly are in progress. Design information and preliminary test results are presented.
Keywords :
Anodes; Assembly; Cathodes; Collimators; Diodes; Impedance; Laboratories; Structural beams; Testing; Voltage;