Title :
A low-noise charge amplifier with fast rise time and active discharge mechanism
Author :
Bassini, Roberto ; Boiano, Ciro ; Pullia, Alberto
Author_Institution :
Ist. Nazionale di Fisica Nucleare (INFN) di Milano, Italy
fDate :
10/1/2002 12:00:00 AM
Abstract :
A new hybrid, low-noise, wide-bandwidth charge amplifier, using a new active discharge mechanism, has been designed and built primarily for gamma-ray tracking detectors, where a fast rise time is required. In order to realize the discharge of the feedback capacitance, a noninverting low-gain (A) stage has been inserted between the output of a conventional charge preamplifier and the high-value feedback resistance. This technique allows to make the discharge time constant shorter (by factor A), while keeping the feedback resistor as the feedback capacitance unchanged. Special care has been devoted realizing the hybrid layout to reduce the stray capacitance of the feedback resistor and particular attention has been dedicated to assure a good signal-to-noise ratio and a fast rise time. A low-power consumption allows the use of this charge-sensitive preamplifier in vacuum chamber without cooling system. The noise level is equivalent to less than 880-eV full width half maximum for an input capacitance of 22 pF, using 3-μs shaping time. The noise grows with a slope of less than 10 eV/pF in the range of 20-60 pF input capacitance. This suggests that the preamplifier can be operated at room temperature maintaining a good noise usually reachable with a cooled setup.
Keywords :
X-ray spectrometers; feedback amplifiers; gamma-ray detection; germanium radiation detectors; nuclear electronics; preamplifiers; pulse height analysers; 20 to 60 pF; 3 mus; 880 eV; Ge; X-ray spectroscopy; active discharge mechanism; charge-sensitive preamplifier; cooling system; fast rise time; feedback capacitance; gamma-ray tracking detectors; high-purity germanium gamma-ray detectors; high-value feedback resistance; low-noise charge amplifier; low-power consumption; noninverting low-gain stage; shaping time; signal-to-noise ratio; vacuum chamber; Broadband amplifiers; Capacitance; Gamma ray detection; Gamma ray detectors; Low-noise amplifiers; Noise shaping; Output feedback; Preamplifiers; Resistors; Signal to noise ratio;
Journal_Title :
Nuclear Science, IEEE Transactions on
DOI :
10.1109/TNS.2002.803865