DocumentCode :
861451
Title :
Comparing electrode configurations for electrical impedance tomography
Author :
Booth, M.J. ; Basarab-Horwath, I.
Author_Institution :
Sch. of Eng. Inf. Technol., Sheffield Hallam Univ., UK
Volume :
32
Issue :
7
fYear :
1996
fDate :
3/28/1996 12:00:00 AM
Firstpage :
648
Lastpage :
649
Abstract :
Several applications of electrical impedance tomography (EIT) exist where the electrodes can be placed within the interrogated region. The image quality and calculated visibility for various sized conducting anomalies were used as measures of performance for three different electrode configurations. A novel distributed electrode configuration showed superior measures of performance
Keywords :
electric impedance imaging; electrodes; image reconstruction; image resolution; tomography; conducting anomalies; distributed electrode; electrical impedance tomography; electrode configurations; image quality; interrogated region; visibility;
fLanguage :
English
Journal_Title :
Electronics Letters
Publisher :
iet
ISSN :
0013-5194
Type :
jour
DOI :
10.1049/el:19960414
Filename :
491876
Link To Document :
بازگشت