DocumentCode :
861638
Title :
Estimation of image noise in PET using the bootstrap method
Author :
Dahlbom, Magnus
Author_Institution :
Dept. of Molecular & Med. Pharmacology, UCLA Sch. of Medicine, Los Angeles, CA, USA
Volume :
49
Issue :
5
fYear :
2002
fDate :
10/1/2002 12:00:00 AM
Firstpage :
2062
Lastpage :
2066
Abstract :
The bootstrap method applied to positron emission tomography (PET) data was evaluated as a technique to determine regional image noise in PET. To validate the method, 250 scans (5 min each) of a uniform cylinder filled with 68Ge was acquired and reconstructed using filtered backprojection (FBP). A single 5-min list mode scan was also acquired. From the list mode data, 250 bootstrap replicates were generated by randomly drawing, with replacement, prompt and random events. In each replicate, the total numbers of prompt and random events were kept identical to the number in the original list mode data set. The 250 individual scans, and the bootstrap replicates, were reconstructed using FBP and ordered subset expectation maximization (OSEM). Mean and standard-deviation (SD) images were generated from the reconstructed images. Mean and SD were also calculated in a central region of the image sets. Visual inspection showed no appreciable difference between the SD images derived from the repeated scans and the bootstrap replicates. Profiles through the images, showed no significant difference between image sets. Using an increased number of bootstrap replicates produced less noise in the SD images. Region of interest analysis showed, that the SDs derived from the bootstrap replicates were very close to the ones derived from the repeat scans, independent of reconstruction algorithm. The results indicate that the bootstrap method can accurately estimate regional image noise in PET. This could potentially provide a method to accurately compare image noise in phantom and patient data under various imaging and processing conditions, without the need for repeat scans.
Keywords :
image reconstruction; positron emission tomography; random noise; 68Ge; OSEM; PET; bootstrap method; filtered backprojection; image noise; ordered subset expectation maximization; positron emission tomography; region of interest; regional image noise; standard-deviation images; Biomedical imaging; Image generation; Image reconstruction; Imaging phantoms; Inspection; Noise measurement; Positron emission tomography; Reconstruction algorithms; Statistical distributions; Whole-body PET;
fLanguage :
English
Journal_Title :
Nuclear Science, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9499
Type :
jour
DOI :
10.1109/TNS.2002.803688
Filename :
1046790
Link To Document :
بازگشت