DocumentCode
862838
Title
The MPS II Drift Chamber System
Author
Eiseman, S. ; Etkin, A. ; Foley, K.J. ; Longacre, R.S. ; Love, W.A. ; Morris, T.W. ; Ozaki, S. ; Platner, E.D. ; Polychronakos, V.A. ; Saulys, A.C. ; Wheeler, C.D. ; Lindenbaum, S.J. ; Kramer, M.A. ; Teramoto, Y.
Author_Institution
Brookhaven National Laboratory, Upton, New York 11973
Volume
30
Issue
1
fYear
1983
Firstpage
149
Lastpage
152
Abstract
A description of this highly integrated drift chamber system is presented. This high resolution and deadtimeless apparatus achieves excellent performance without channel-by-channel parameter corrections. This approach is suited for very large drift chamber systems since it contains an average of less than one active component per channel. In addition to a description of the system, results from beam tests, and actual use in an experiment are discussed.
Keywords
Anodes; Cathodes; Cities and towns; Contracts; Detectors; Educational institutions; Integrated circuit noise; Laboratories; Voltage; Wires;
fLanguage
English
Journal_Title
Nuclear Science, IEEE Transactions on
Publisher
ieee
ISSN
0018-9499
Type
jour
DOI
10.1109/TNS.1983.4332240
Filename
4332240
Link To Document