Title
Time Measurement with a Multiphase Clock
Author
Dhawan, Satish K.
Author_Institution
J. W. Gibbs Laboratory Yale University New Haven, CT 06511, U.S.A.
Volume
30
Issue
1
fYear
1983
Firstpage
293
Lastpage
296
Abstract
A multiphase clock is used to measure time intervals. The scheme consists of a main counter and digital verniers for start and stop. The system time resolution is limited by the intrinsic resolving time of the circuits rather than the clock rate. A 7 phase clock of ~28.57 MHz can measure time to 2.5 nsec accuracy with T2L type circuits.