• DocumentCode
    863261
  • Title

    Improved Energy Resolution Capability of an Imaging Proportional Counter Using Electron Counting Techniques

  • Author

    Siegmund, O.H.W. ; Clothier, S. ; Culhane, J.L. ; Mason, I.M.

  • Author_Institution
    Mullard Space Science Laboratory, University College London, Holmbury St Mary, Dorking, Surrey RH5 6NT, UK
  • Volume
    30
  • Issue
    1
  • fYear
    1983
  • Firstpage
    350
  • Lastpage
    354
  • Abstract
    The number of electrons initially created by the absorption of a soft X-ray photon in a parallel plate proportional counter may be counted by detection of the fast light pulses emitted from the resulting electron avalanches. We show that good energy resolution may be achieved (~34% at C-K, 0.28 keV) with this technique. Using the light signal it is also possible to image events by means of an image intensifier, and position resolution of 350 ¿m FWHM at 0.28 keV has been achieved without event centroiding.
  • Keywords
    Counting circuits; Electromagnetic wave absorption; Electron emission; Energy resolution; Fast light; Image intensifiers; Optical imaging; X-ray detection; X-ray detectors; X-ray imaging;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/TNS.1983.4332286
  • Filename
    4332286