• DocumentCode
    863688
  • Title

    Pocket Neutron REM Meter

  • Author

    Quam, W. ; Del Duca, T. ; Plake, W. ; Graves, G. ; DeVore, T. ; Warren, J.

  • Author_Institution
    EG&G, Santa Barbara Operations 130 Robin Hill Road Goleta, California 93116
  • Volume
    30
  • Issue
    1
  • fYear
    1983
  • Firstpage
    547
  • Lastpage
    550
  • Abstract
    This paper describes a pocket-calculator-sized, neutron-sensitive, REM-responding personnel dosimeter that uses three tissue-equivalent cylindrical proportional counters as neutron-sensitive detectors. These are conventionally called Linear Energy Transfer (LET) counters. Miniaturized hybrid circuits are used for the linear pulse handling electronics, followed by a 256-channel ADC. A CMOS microprocessor is used to calculate REM exposure from the basic rads-tissue data supplied by the LET counters and also to provide timing and display functions. The instrument is used to continuously accumulate time in hours since reset, total counts accumulated, rads-tissue, and REM. The user can display any one of these items or a channel number (an aid in calibration) at any time. Such data are provided with a precision of ±3% for a total exposure of 1 mREM over eight hours.
  • Keywords
    Counting circuits; Detectors; Displays; Energy exchange; Instruments; Microprocessors; Neutrons; Personnel; Pulse circuits; Timing;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/TNS.1983.4332330
  • Filename
    4332330