DocumentCode
864003
Title
Preimage Selection in Time-of-Flight Emission Tomography
Author
Snyder, Donald L.
Author_Institution
Washington University St. Louis, Missouri 63110
Volume
30
Issue
1
fYear
1983
Firstpage
701
Lastpage
702
Abstract
The confidence-weighted preimage is shown to have a "minimax" property such that it minimizes the worst case reconstruction error among all two-dimensional preimages derived linearly from three-dimensional, list-mode data, including the most likely position and profile preimages. However, we argue that improved performance can be obtained by not producing two-dimensional data from three-dimensional, list-mode data.
Keywords
Convolution; Density measurement; Event detection; Fourier transforms; Image reconstruction; Instruments; Minimax techniques; Position measurement; Tomography; Upper bound;