DocumentCode :
864078
Title :
Continuous measurement of moisture in nonconducting materials
Author :
Vermeulen, Clinton ; Hancke, Gerhard P.
Author_Institution :
Dept. of Electr. & Electron. Eng., Pretoria Univ., South Africa
Volume :
41
Issue :
6
fYear :
1992
fDate :
12/1/1992 12:00:00 AM
Firstpage :
1023
Lastpage :
1026
Abstract :
A microwave-based system for the continuous measurement of moisture in nonconducting materials is described. The system was implemented on conveyor belts carrying coarse coal. To obtain a reliable measurement for this application, several other factors which influence the microwave measurement technique had to be investigated. These factors are, among others, the mass per unit area and the temperature. The measurement of these factors makes possible the general characterization of the coal, which is important for optimizing the utilization of the coal for various applications
Keywords :
coal; microwave measurement; moisture measurement; coarse coal; continuous measurement; conveyor belts; microwave measurement; moisture measurement; nonconducting materials; Dielectric constant; Dielectric loss measurement; Dielectric losses; Dielectric materials; Dielectric measurements; Microwave devices; Microwave measurements; Microwave theory and techniques; Moisture measurement; Permittivity measurement;
fLanguage :
English
Journal_Title :
Instrumentation and Measurement, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9456
Type :
jour
DOI :
10.1109/19.199386
Filename :
199386
Link To Document :