DocumentCode
865507
Title
PIXE Analysis of Aerosol in the Workplace
Author
Williams, Evan T. ; Punyasena, Lahanda W.
Author_Institution
Department of Chemistry, City University of New York Brooklyn College Brooklyn, New York, 11210
Volume
30
Issue
2
fYear
1983
fDate
4/1/1983 12:00:00 AM
Firstpage
1294
Lastpage
1297
Abstract
Sampling programs of relatively limited extent can be useful for monitoring suspended particulate matter in specific locations; for example certain occupational situations. Aerosol samples were collected by cascade impactors and analyzed by PIXE at the Brooklyn College Dynamitron Laboratory. We describe the results of experiments in a metal-sculpture studio involving silver soldering, an industrial plastics-milling shop and a municipal incinerator.
Keywords
Aerosols; Educational institutions; Employment; Laboratories; Metals industry; Monitoring; Plastics industry; Sampling methods; Silver; Soldering;
fLanguage
English
Journal_Title
Nuclear Science, IEEE Transactions on
Publisher
ieee
ISSN
0018-9499
Type
jour
DOI
10.1109/TNS.1983.4332513
Filename
4332513