DocumentCode
865618
Title
The Determination of Platinum in Human Tissues with PIXE
Author
Dikhoff, T.G.M.H. ; van der Heide, J.A. ; Prins, M. ; Vie, J. G Mc
Author_Institution
Eindhoven University of Technology, 5612 AZ Eindhoven, The Netherlands
Volume
30
Issue
2
fYear
1983
fDate
4/1/1983 12:00:00 AM
Firstpage
1329
Lastpage
1331
Abstract
Platinum levels as well as trace element concentrations in samples from cis-platin treated patients have been measured using the PIXE technique. The results were verified by neutron activation analysis for some elements. Spectral interferences of the platinum Là peak and selenium K¿ have been solved by introducing a germanium layer as a selective absorber. The experiments are done in the frame work of a project on the assesment of the toxicity of cytostatic platinum compounds. Preliminary results for liver, kidney and heart tissues are shown.
Keywords
Activation analysis; Heart; Humans; Liver; Medical treatment; Neutrons; Plasma measurements; Platinum; X-ray detection; Yttrium;
fLanguage
English
Journal_Title
Nuclear Science, IEEE Transactions on
Publisher
ieee
ISSN
0018-9499
Type
jour
DOI
10.1109/TNS.1983.4332523
Filename
4332523
Link To Document