DocumentCode :
866471
Title :
Status of a Pulsed-Neutron Logging Probe Using a High-Purity Germanium Detector
Author :
Jensen, D.H. ; Barnard, R.W. ; Bivens, H.M. ; Humphreys, D.R. ; Weinlein, J.H. ; Stephenson, W.A.
Author_Institution :
Sandia National Laboratories, Albuquerque, New Mexico 87185
Volume :
30
Issue :
2
fYear :
1983
fDate :
4/1/1983 12:00:00 AM
Firstpage :
1657
Lastpage :
1663
Abstract :
The development of a logging tool which has the potential for identifying a large number of elements in a borehole configuration has been described. Most problems with the tool have been resolved, and the results presently obtained are encouraging. The analysis of the data taken with the multi-element tool is presently only qualitative for the active spectra, with the identification of lines from several elements including Ge, Na, Cr, Mo, Fe, H, Si, Cl, Ca, Al, Mg, and Co. The development of techniques for obtaining quantitative data for these elements and others should begin in 1983.
Keywords :
Coaxial cables; Gamma ray detection; Gamma ray detectors; Germanium; Neutrons; Packaging; Power generation; Probes; Pulse generation; Pulse transformers;
fLanguage :
English
Journal_Title :
Nuclear Science, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9499
Type :
jour
DOI :
10.1109/TNS.1983.4332609
Filename :
4332609
Link To Document :
بازگشت