DocumentCode :
867882
Title :
An Ionization Profile Monitor for the Brookhaven AGS
Author :
Weisberg, H. ; Gill, E. ; Ingrassia, P. ; Rodger, E.
Author_Institution :
Brookhaven National Laboratory, Upton, NY 11973
Volume :
30
Issue :
4
fYear :
1983
Firstpage :
2179
Lastpage :
2181
Abstract :
A non-destructive internal emittance device has been built for the AGS, with separate units to measure the horizontal and vertical profiles of the circulating beam. Positive ions from collisions of the beam with background gas are collected in a 3-kV/cm electric field onto a 64-channel parallel strip detector. Because positive ions rather than electrons are collected, profile broadening due to space charge is small. Tests indicate that a quantitative, reproducible and accurate measurement of beam size throughout the acceleration cycle is provided.
Keywords :
Electrons; Ionization; Life estimation; Measurement units; Monitoring; Particle beams; Size measurement; Space charge; Strips; Testing;
fLanguage :
English
Journal_Title :
Nuclear Science, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9499
Type :
jour
DOI :
10.1109/TNS.1983.4332753
Filename :
4332753
Link To Document :