• DocumentCode
    867928
  • Title

    Beam Diagnostic Instrumentation at CESR

  • Author

    Rice, D. ; Aharonian, G. ; Adams, K. ; Billing, M. ; Decker, G. ; Dunnam, C. ; Giannella, M. ; Jackson, G. ; Littauer, R. ; McDaniel, B. ; Morse, D. ; Peck, S. ; Sakazaki, L. ; Seeman, J. ; Siemann, R. ; Talman, R.

  • Author_Institution
    Cornell University, Ithaca, New York, 14853
  • Volume
    30
  • Issue
    4
  • fYear
    1983
  • Firstpage
    2190
  • Lastpage
    2192
  • Abstract
    We discribe various beam diagnostic devices in use at CESR, an 8 GeV electron-positron storage ring operating primarily in the 4.7 to 5.5 GeV beam energy range. Getting the last 20% of performance depends to some extent on empirical tuning and appropriate presentation of various parameters is very important. Several devices are most useful in machine studies and we describe their operation. The individually regulated quadrupoles in CESR provide unique opportunities for lattice measurements and calibration of beam position monitors.
  • Keywords
    Calibration; Circuit faults; Computer displays; Ferrites; Frequency; Instruments; Monitoring; Spectral analysis; Synchrotrons; Tuning;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/TNS.1983.4332757
  • Filename
    4332757