DocumentCode
867928
Title
Beam Diagnostic Instrumentation at CESR
Author
Rice, D. ; Aharonian, G. ; Adams, K. ; Billing, M. ; Decker, G. ; Dunnam, C. ; Giannella, M. ; Jackson, G. ; Littauer, R. ; McDaniel, B. ; Morse, D. ; Peck, S. ; Sakazaki, L. ; Seeman, J. ; Siemann, R. ; Talman, R.
Author_Institution
Cornell University, Ithaca, New York, 14853
Volume
30
Issue
4
fYear
1983
Firstpage
2190
Lastpage
2192
Abstract
We discribe various beam diagnostic devices in use at CESR, an 8 GeV electron-positron storage ring operating primarily in the 4.7 to 5.5 GeV beam energy range. Getting the last 20% of performance depends to some extent on empirical tuning and appropriate presentation of various parameters is very important. Several devices are most useful in machine studies and we describe their operation. The individually regulated quadrupoles in CESR provide unique opportunities for lattice measurements and calibration of beam position monitors.
Keywords
Calibration; Circuit faults; Computer displays; Ferrites; Frequency; Instruments; Monitoring; Spectral analysis; Synchrotrons; Tuning;