DocumentCode :
867928
Title :
Beam Diagnostic Instrumentation at CESR
Author :
Rice, D. ; Aharonian, G. ; Adams, K. ; Billing, M. ; Decker, G. ; Dunnam, C. ; Giannella, M. ; Jackson, G. ; Littauer, R. ; McDaniel, B. ; Morse, D. ; Peck, S. ; Sakazaki, L. ; Seeman, J. ; Siemann, R. ; Talman, R.
Author_Institution :
Cornell University, Ithaca, New York, 14853
Volume :
30
Issue :
4
fYear :
1983
Firstpage :
2190
Lastpage :
2192
Abstract :
We discribe various beam diagnostic devices in use at CESR, an 8 GeV electron-positron storage ring operating primarily in the 4.7 to 5.5 GeV beam energy range. Getting the last 20% of performance depends to some extent on empirical tuning and appropriate presentation of various parameters is very important. Several devices are most useful in machine studies and we describe their operation. The individually regulated quadrupoles in CESR provide unique opportunities for lattice measurements and calibration of beam position monitors.
Keywords :
Calibration; Circuit faults; Computer displays; Ferrites; Frequency; Instruments; Monitoring; Spectral analysis; Synchrotrons; Tuning;
fLanguage :
English
Journal_Title :
Nuclear Science, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9499
Type :
jour
DOI :
10.1109/TNS.1983.4332757
Filename :
4332757
Link To Document :
بازگشت