• DocumentCode
    868527
  • Title

    Measurement of Bunch Length with an Image Dissector Tube

  • Author

    Brown, G.S. ; Suller, V.P. ; Zinin, E.

  • Author_Institution
    SERC, Daresbury Laboratory, Daresbury, Warrington WA4 4AD, U.K.
  • Volume
    30
  • Issue
    4
  • fYear
    1983
  • Firstpage
    2348
  • Lastpage
    2350
  • Abstract
    The length of the electron bunches in the SRS storage ring has been measured by focusing the synchrotron light onto an image dissector tube. The technique is described, which is applicable both to the single bunch mode and to the multibunch mode. Bunch lengths of approximately 0.2 ns are measured with a resolution of 0.05 ns.
  • Keywords
    Cameras; Cathodes; Electron beams; Electron tubes; Focusing; Frequency; Length measurement; Signal resolution; Storage rings; Synchrotrons;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/TNS.1983.4332812
  • Filename
    4332812