Measurement of Bunch Length with an Image Dissector Tube
Author
Brown, G.S. ; Suller, V.P. ; Zinin, E.
Author_Institution
SERC, Daresbury Laboratory, Daresbury, Warrington WA4 4AD, U.K.
Volume
30
Issue
4
fYear
1983
Firstpage
2348
Lastpage
2350
Abstract
The length of the electron bunches in the SRS storage ring has been measured by focusing the synchrotron light onto an image dissector tube. The technique is described, which is applicable both to the single bunch mode and to the multibunch mode. Bunch lengths of approximately 0.2 ns are measured with a resolution of 0.05 ns.