Title :
Spark-Gap Crowbar for High-Voltage Power Supply
Author :
Mitra, A.K. ; Tallerico, P.J.
Author_Institution :
AT-5, MS H827 Los Alamos National Laboratory, Los Alamos, NM 87545
Abstract :
A new crowbar circuit employing a pressurized spark gap has been designed to replace the existing ignitron crowbar that protects a 500-kW klystron tube when it arcs. The spark gap offers definite performance advantages when compared to the conventional ignitron circuits. The small overall size makes the spark gap more convenient and the very few components make it more reliable than the ignitron crowbar.
Keywords :
Circuit breakers; Circuit testing; Fires; Fuel storage; Klystrons; Optical transmitters; Power supplies; Protection; Spark gaps; Vacuum arcs;
Journal_Title :
Nuclear Science, IEEE Transactions on
DOI :
10.1109/TNS.1983.4332980