• DocumentCode
    870532
  • Title

    A VAX Based Data Acquisition Computer System at the Nuclear Structure Research Laboratory

  • Author

    Clark, D.L. ; Lund, T.S. ; Melvin, J.D.

  • Author_Institution
    Nuclear Structure Research Laboratory University of Rochester Rochester, New York 14627
  • Volume
    30
  • Issue
    5
  • fYear
    1983
  • Firstpage
    3804
  • Lastpage
    3807
  • Abstract
    The Nuclear Structure Research Laboratory at the University of Rochester is developing a VAX-11/750 computer system for use in a data acquisition and analysis system. The system consists of the VAX which is networked to two LSI-11/23´s which are in turn connected to CAMAC branch drivers. The CAMAC branch drivers operate both parallel and 5 MHz byte-serial highways. The network is a high speed DMA interface and is identical to the system implemented at the W.K. Kellogg Radiation Laboratory[l]. The data acquisition system has been designed to allow the user to select standard program modules as building blocks to construct a system to suit the particular needs of the experiment. The division of the realtime analysis between the VAX and the LSI-11s is flexible. The LSI-11s are equipped with small array processors tlo permit high speed analysis on the satellite processors.
  • Keywords
    CAMAC; Computer networks; Data acquisition; Data analysis; Displays; Graphics; Hardware; Laboratories; Power system reliability; Satellites;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/TNS.1983.4333014
  • Filename
    4333014