• DocumentCode
    871773
  • Title

    Comparison of 60Co Response and 10 KeV X-Ray Response in MOS Capacitors

  • Author

    Oldham, T.R. ; McGarrity, J.M.

  • Author_Institution
    U. S. Army Electronics Research and Development Command Harry Diamond Laboratories Adelphi, Maryland 20783
  • Volume
    30
  • Issue
    6
  • fYear
    1983
  • Firstpage
    4377
  • Lastpage
    4381
  • Abstract
    Recently there has been great practical interest in using low energy (10 keV) x-rays rather than the usual 60Co for radiation testing of microelectronic circuits. In this work we examine some of the mechanisms underlying the radiation response of MOS capacitors in these two environments. Specifically we measure the thickness dependent dose enhancement in thin SiO2 films, and we measure the field dependence of the recombination. We found significant dose enhancement for 10 keV x-rays for thin oxides, and the recombination is generally greater at field of practical interest for 10 keV x-rays than for 60Co. The implications of these results for device testing are discussed.
  • Keywords
    Circuit testing; Electron tubes; Electronic equipment testing; Electronics packaging; Laboratories; MOS capacitors; Microelectronics; Research and development; Thickness measurement; Tungsten;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/TNS.1983.4333141
  • Filename
    4333141