  • Abstract
    A method is given for stabilising and setting the measurement centre frequency of the Hewlett Packard 8970A noise figure meter to prevent significant errors in noise measurements of highly mismatched devices. The method requires a simple modification to the instrument.
  • Keywords
    electric noise measurement; frequency stability; measurement errors; microwave measurement; 1 to 2 GHz; Hewlett Packard 8970A noise figure meter; frequency stabilisation; highly mismatched devices; measurement centre frequency; measurement error prevention; microwave noise measurements;