DocumentCode :
872885
Title :
Experience with a FASTBUS Based Data Acqutisition System for Imaging Coronary Arteries
Author :
Siskind, Eric J. ; Ong, L. ; Srinivasan, M. ; Frost, M. ; Reiser, P. ; Morrison, J.
Author_Institution :
NYCB Real-Time Computing, Inc. Port Washington, NY 11050
Volume :
31
Issue :
1
fYear :
1984
Firstpage :
230
Lastpage :
235
Abstract :
The design specifications, hardware features, performance, and development costs of a FASTBUS based data acquisition system for transporting image data under the control of a VAX-11/780 computing system are described. The system currently transports digitized images from a television camera running at up to 16 bits per pixel, 512 pixels per scan line, 512 lines per frame, and 30 frames per second via FASTBUS into a large bulk memory by employing no-handshake (MS=3) block transfers at a 148 megabyte/second transfer rate.
Keywords :
Arteries; Biomedical imaging; Cameras; Cardiology; Control systems; Data acquisition; Fastbus; Hardware; Hospitals; Pixel;
fLanguage :
English
Journal_Title :
Nuclear Science, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9499
Type :
jour
DOI :
10.1109/TNS.1984.4333252
Filename :
4333252