Title :
Errors in Dielectric Measurements Due to a Sample Insertion Hole in a Cavity
Author :
Bussey, H.E. ; Estin, A.J.
fDate :
11/1/1960 12:00:00 AM
Abstract :
The measurement of complex permittivities of isotropic media at microwave frequencies is performed with high precision by means of cylindrical cavity resonators. However, a hole in the cavity wall, for inserting the sample causes a frequency pulling of the resonator, which in turn introduces an error in the measured dielectric constant. These effects are measured, and with perturbation theory as a guide, correction factors are developed.
Keywords :
Cavity resonators; Dielectric constant; Dielectric materials; Dielectric measurements; Frequency measurement; Microwave measurements; Permittivity measurement; Plugs; Solids; Wavelength measurement;
Journal_Title :
Microwave Theory and Techniques, IRE Transactions on
DOI :
10.1109/TMTT.1960.1124812