DocumentCode :
873419
Title :
Dynamic mechanical response of elastic spherical inclusions to impulsive acoustic radiation force excitation
Author :
Palmeri, Mark L. ; McAleavey, Stephen A. ; Fong, Kelly L. ; Trahey, Gregg E. ; Nightingale, Kathryn R.
Author_Institution :
Dept. of Biomed. Eng., Duke Univ., Durham, NC
Volume :
53
Issue :
11
fYear :
2006
fDate :
11/1/2006 12:00:00 AM
Firstpage :
2065
Lastpage :
2079
Abstract :
Acoustic radiation force impulse imaging has been used clinically to study the dynamic response of lesions relative to their background material to focused, impulsive acoustic radiation force excitations through the generation of dynamic displacement field images. Dynamic displacement data are typically displayed as a set of parametric images, including displacement immediately after excitation, maximum displacement, time to peak displacement, and recovery time from peak displacement. To date, however, no definitive trends have been established between these parametric images and the tissues´ mechanical properties. This work demonstrates that displacement magnitude, time to peak displacement, and recovery time are all inversely related to the Young´s modulus in homogeneous elastic media. Experimentally, pulse repetition frequency during displacement tracking limits stiffness resolution using the time to peak displacement parameter. The excitation pulse duration also impacts the time to peak parameter, with longer pulses reducing the inertial effects present during impulsive excitations. Material density affects tissue dynamics, but is not expected to play a significant role in biological tissues. The presence of an elastic spherical inclusion in the imaged medium significantly alters the tissue dynamics in response to impulsive, focused acoustic radiation force excitations. Times to peak displacement for excitations within and outside an elastic inclusion are still indicative of local material stiffness; however, recovery times are altered due to the reflection and transmission of shear waves at the inclusion boundaries. These shear wave interactions cause stiffer inclusions to appear to be displaced longer than the more compliant background material. The magnitude of shear waves reflected at elastic lesion boundaries is dependent on the stiffness contrast between the inclusion and the background material, and the stiffness and size of the inclusion dictate when s- - hear wave reflections within the lesion will interfere with one another. Jitter and bias associated with the ultrasonic displacement tracking also impact the estimation of a tissue´s dynamic response to acoustic radiation force excitation
Keywords :
Young´s modulus; biological tissues; biomechanics; biomedical ultrasonics; elastic waves; Jitter; Young´s modulus; acoustic radiation force impulse imaging; bias; displacement magnitude; dynamic displacement field images; dynamic mechanical response; elastic spherical inclusion; elastic spherical inclusions; excitation pulse duration; homogeneous elastic media; impulsive acoustic radiation force excitation; lesions; material density; maximum displacement; pulse repetition frequency; recovery time; shear waves; stiffness resolution; time to peak displacement; tissue dynamics; ultrasonic displacement tracking; Acoustic imaging; Acoustic materials; Acoustic pulses; Acoustic reflection; Biological materials; Biological tissues; Focusing; Frequency; Lesions; Mechanical factors;
fLanguage :
English
Journal_Title :
Ultrasonics, Ferroelectrics, and Frequency Control, IEEE Transactions on
Publisher :
ieee
ISSN :
0885-3010
Type :
jour
DOI :
10.1109/TUFFC.2006.146
Filename :
4037214
Link To Document :
بازگشت