Title :
A new active cavitation mapping technique for pulsed HIFU applications-bubble doppler
Author :
Tong Li ; Khokhlova, Tatiana ; Sapozhnikov, Oleg ; O´Donnell, Matthew ; Hwang, Jae-Sang
Author_Institution :
Appl. Phys. Lab., Univ. of Washington, Seattle, WA, USA
Abstract :
In this work, a new active cavitation mapping technique for pulsed high-intensity focused ultrasound (pHIFU) applications termed bubble Doppler is proposed and its feasibility is tested in tissue-mimicking gel phantoms. pHIFU therapy uses short pulses, delivered at low pulse repetition frequency, to cause transient bubble activity that has been shown to enhance drug and gene delivery to tissues. The current gold standard for detecting and monitoring cavitation activity during pHIFU treatments is passive cavitation detection (PCD), which provides minimal information on the spatial distribution of the bubbles. B-mode imaging can detect hyperecho formation, but has very limited sensitivity, especially to small, transient microbubbles. The bubble Doppler method proposed here is based on a fusion of the adaptations of three Doppler techniques that had been previously developed for imaging of ultrasound contrast agents-color Doppler, pulse-inversion Doppler, and decorrelation Doppler. Doppler ensemble pulses were interleaved with therapeutic pHIFU pulses using three different pulse sequences and standard Doppler processing was applied to the received echoes. The information yielded by each of the techniques on the distribution and characteristics of pHIFU-induced cavitation bubbles was evaluated separately, and found to be complementary. The unified approach-bubble Doppler-was then proposed to both spatially map the presence of transient bubbles and to estimate their sizes and the degree of nonlinearity.
Keywords :
Doppler measurement; biological tissues; bubbles; cavitation; drug delivery systems; flow visualisation; gene therapy; phantoms; ultrasonic therapy; B-mode imaging; Doppler ensemble pulses; active cavitation mapping technique; cavitation bubbles; color Doppler; decorrelation Doppler; drug delivery; gene delivery; hyperecho formation; nonlinearity degree; passive cavitation detection; pulse repetition frequency; pulse sequences; pulse-inversion Doppler; pulsed high-intensity focused ultrasound therapy; spatial bubble distribution; tissue-mimicking gel phantoms; transient bubble activity; transient microbubbles; ultrasound contrast agent imaging; unified approach-bubble Doppler; Doppler effect; Image color analysis; Phantoms; Probes; Transducers; Ultrasonic imaging;
Journal_Title :
Ultrasonics, Ferroelectrics, and Frequency Control, IEEE Transactions on
DOI :
10.1109/TUFFC.2014.006502