• DocumentCode
    873885
  • Title

    High Precision 85Kr Monitor

  • Author

    Fernandez, S.J. ; Anderson, M.D. ; Motes, B.G. ; Chapman, T.C. ; Emel, W.A. ; Tkachyk, J.W.

  • Author_Institution
    Exxon Nuclear Idaho Co., P.O. Box 2800, Idaho Falls, ID 83401
  • Volume
    31
  • Issue
    1
  • fYear
    1984
  • Firstpage
    682
  • Lastpage
    685
  • Abstract
    The development of a 85Kr off-gas monitor for nuclear fuel reprocessing plants is presented. Discussed are the parameters used in the design of the monitor, including the sensitivity, the dynamic measurement range, and the radionuclide composition of the off-gas stream. Detailed are the associated isokinetic sampling system, the components of the monitor, and the data acquisition microprocessor. Lastly, 85Kr rel eases measured during in-plant demonstration of the monitor are compared with known 85Kr releases.
  • Keywords
    Chemical elements; Condition monitoring; Gamma ray detection; Gamma ray detectors; Interference; Laboratories; Nuclear fuels; Optical films; Radiation detectors; Spectroscopy;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/TNS.1984.4333346
  • Filename
    4333346