Title
The High Voltage Perturbation Technique for Testing the Response of Neutron Sensors of the Type Used in Nuclear Reactors
Author
Talnagi, J.W. ; Arndt, S.A. ; Behbahani, A. ; Miller, D.W.
Author_Institution
The Ohio State University Nuclear Engineering Program 206 West Eighteenth Avenue Columbus, Ohio 43210
Volume
31
Issue
1
fYear
1984
Firstpage
717
Lastpage
720
Abstract
Perturbation of the high voltage bias supply of neutron sensors of the type used in nuclear reactor protection systems has been demonstrated in a laboratory environment to be a potential method for response time measurement. The laboratory evaluation used simulated sensor and signal cable degradation with boron lined and uranium lined chambers operating in current mode. The investigations have demonstrated the sensitivity of the technique for detecting simulated degradations of the time response of the simulated detector-cable system.
Keywords
Degradation; Delay; Neutrons; Nuclear measurements; Perturbation methods; Protection; Sensor systems; Testing; Time measurement; Voltage;
fLanguage
English
Journal_Title
Nuclear Science, IEEE Transactions on
Publisher
ieee
ISSN
0018-9499
Type
jour
DOI
10.1109/TNS.1984.4333353
Filename
4333353
Link To Document