  • Title

    The High Voltage Perturbation Technique for Testing the Response of Neutron Sensors of the Type Used in Nuclear Reactors

  • Author

    Talnagi, J.W. ; Arndt, S.A. ; Behbahani, A. ; Miller, D.W.

  • Author_Institution
    The Ohio State University Nuclear Engineering Program 206 West Eighteenth Avenue Columbus, Ohio 43210
  • Volume
    31
  • Issue
    1
  • fYear
    1984
  • Firstpage
    717
  • Lastpage
    720
  • Abstract
    Perturbation of the high voltage bias supply of neutron sensors of the type used in nuclear reactor protection systems has been demonstrated in a laboratory environment to be a potential method for response time measurement. The laboratory evaluation used simulated sensor and signal cable degradation with boron lined and uranium lined chambers operating in current mode. The investigations have demonstrated the sensitivity of the technique for detecting simulated degradations of the time response of the simulated detector-cable system.
  • Keywords
    Degradation; Delay; Neutrons; Nuclear measurements; Perturbation methods; Protection; Sensor systems; Testing; Time measurement; Voltage;