    Nonlinear propagation of ultrasound through microbubble contrast agents and implications for imaging

  • Author

    Tang, Meng-Xing ; Eckersley, Robert J.

  • Author_Institution
    Dept. of Bioeng., Imperial Coll. London
  • Volume
    53
  • Issue
    12
  • fYear
    2006
  • fDate
    12/1/2006 12:00:00 AM
  • Firstpage
    2406
  • Lastpage
    2415
  • Abstract
    Microbubble contrast agents produce nonlinear echoes under ultrasound insonation, and current imaging techniques detect these nonlinear echoes to generate contrast agent images accordingly. For these techniques, there is a potential problem in that bubbles along the ultrasound transmission path between transducer and target can alter the ultrasound transmission nonlinearly and contribute to the nonlinear echoes. This can lead to imaging artefacts, especially in regions at depth. In this paper we provide insight, through both simulation and experimental measurement, into the nonlinear propagation caused by microbubbles and the implications for current imaging techniques. A series of investigations at frequencies below, at, and above the resonance frequency of microbubbles were performed. Three specific effects on the pulse propagation (i.e., amplitude attenuation, phase changes, and harmonic generation) were studied. It was found that all these effects are dependent on the initial pulse amplitude, and their dependence on the initial phase of the pulse is shown to be insignificant. Two types of imaging errors are shown to result from this nonlinear propagation: first, that tissue can be misclassified as microbubbles; second, the concentration of microbubbles in the image can be misrepresented. It is found that these imaging errors are significant for all three pulse frequencies when the pulses transmit through a microbubble suspension of 6 cm in path length. It also is found that the first type of error is larger at the bubble resonance frequency
  • Keywords
    biomedical ultrasonics; bubbles; nonlinear acoustics; ultrasonic imaging; ultrasonic transmission; amplitude attenuation; bubble resonance frequency; harmonic generation; imaging artefacts; microbubble contrast agents; microbubble suspension; nonlinear echoe; nonlinear ultrasonic propagation; phase change; pulse propagation; ultrasonic imaging; ultrasound insonation; ultrasound transmission path; Absorption; Acoustic scattering; Amplitude modulation; Biomedical engineering; Biomedical imaging; Pulse inverters; Resonance; Resonant frequency; Ultrasonic imaging; Ultrasonic variables measurement;
  • fLanguage
    English
  • Journal_Title
    Ultrasonics, Ferroelectrics, and Frequency Control, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0885-3010
  • Type

    jour

  • DOI
    10.1109/TUFFC.2006.189
  • Filename
    4037277