• DocumentCode
    87435
  • Title

    Automatic optimal input command for linearization of cMUT output by a temporal target

  • Author

    Menigot, Sebastien ; Certon, Dominique ; Gross, Dominic ; Girault, Jean-Marc

  • Author_Institution
    IUT Ville d´Avray, Univ. Paris Ouest Nantere La Defense, Paris, France
  • Volume
    61
  • Issue
    10
  • fYear
    2014
  • fDate
    Oct. 2014
  • Firstpage
    1742
  • Lastpage
    1753
  • Abstract
    Capacitive micromachined ultrasonic transducers (cMUTs) are a promising alternative to the piezoelectric transducer. However, their native nonlinear behavior is a limitation for their use in medical ultrasound applications. Several methods based on the pre-compensation of a preselected input voltage have been proposed to cancel out the harmonic components generated. Unfortunately, these existing pre-compensation methods have two major flaws. The first is that the pre-compensation procedure is not generally automatic, and the second is that they can only reduce the second harmonic component. This can, therefore, limit their use for some imaging methods, which require a broader bandwidth, e.g., to receive the third harmonic component. In this study, we generalized the presetting methods to reduce all nonlinearities in the cMUT output. Our automatic pre-compensation method can work whatever the excitation waveform. The precompensation method is based on the nonlinear modeling of harmonic components from a Volterra decomposition in which the parameters are evaluated by using a Nelder-Mead algorithm. To validate the feasibility of this approach, the method was applied to an element of a linear array with several types of excitation often encountered in encoded ultrasound imaging. The results showed that the nonlinear components were reduced by up to 21.2 dB.
  • Keywords
    Volterra equations; capacitive sensors; ultrasonic transducers; Nelder-Mead algorithm; Volterra decomposition; automatic optimal input command; automatic precompensation method; capacitive micromachined ultrasonic transducer output linearization; encoded ultrasound imaging; excitation waveform; harmonic components; imaging methods; linear array element; medical ultrasound applications; native nonlinear behavior; nonlinear components; nonlinear modeling; preselected input voltage precompensation; temporal target; Acoustics; Bandwidth; Harmonic analysis; Imaging; Optimization; Probes; Transducers;
  • fLanguage
    English
  • Journal_Title
    Ultrasonics, Ferroelectrics, and Frequency Control, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0885-3010
  • Type

    jour

  • DOI
    10.1109/TUFFC.2013.006330
  • Filename
    6910384