Abstract :
Values of R/Qf or re-entrant resonators are given for configurations for which neither the coaxial-field nor the radial-field approximations are valid. The values are calculated by net point methods, and agree well with experimental values obtained by perturbation methods. Some errors arising from the finite dimensions of perturbing plungers are also discussed.
Keywords :
Accuracy; Coaxial components; Frequency estimation; Gyroscopes; Impedance measurement; Klystrons; Maxwell equations; Perturbation methods; Q measurement; Resonant frequency;