• DocumentCode
    874925
  • Title

    Monte Carlo Calculations of Irradiation Test Photon Spectra

  • Author

    Woolf, S. ; Burke, E.A.

  • Author_Institution
    ARCON Corporation, 260 Bear Hill Road Waltham, MA 02154
  • Volume
    31
  • Issue
    6
  • fYear
    1984
  • Firstpage
    1089
  • Lastpage
    1094
  • Abstract
    Calculations of scattered photon spectra in concrete rooms are made, by means of the Monte Carlo method, for Co-60 sources of the type used in irradiation testing of electronic devices. It is found that the scattered photon spectrum shape is heavily dependent on the location of source and target, and that in devices where dose enhancement can occur, there can be substantial variation in the absorbed dose due to this strong dependence on location. Scattered photon spectra are also obtained for two types of irradiation test cells. Additionally, dose enhancement ratios obtained with a coupled photon-electron Monte Carlo calculation are given for a gold-metallized silicon device.
  • Keywords
    Building materials; Concrete; Electromagnetic scattering; Electronic equipment testing; Gamma ray detection; Gold; Materials testing; Monte Carlo methods; Particle scattering; Water resources;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/TNS.1984.4333461
  • Filename
    4333461