Title :
DO Data Acquisition Design
Author :
Cutts, D. ; Hoftun, J.S. ; Zeller, R.T. ; Trojak, T. ; Van Berg, R. ; Johnson, C.R. ; Zeller, R.T.
Author_Institution :
Physics Dept., Brown University Providence, RI
Abstract :
The new generation of colliding beam experiments require new and more powerful systems for data acquisition. The DO experiment at Fermilab´s Tevatron-I employs a multi-level trigger system to reduce the primary interaction rate of 50 KHz. to an event recording rate of 1-2 Hz. We describe the DO acquisition system, focusing primarily on the second level, which is based on a large parallel array of MicroVAX-II´s. Data flows from the detector readout crates at a maximum rate of 320 Mbytes/sec into dual-port memories associated with one selected processor in which a VAXELN based program performs the filter analysis of a complete event.
Keywords :
Data acquisition; Event detection; Fastbus; Filters; Hardware; Mesons; Performance analysis; Physics; Power generation; Radiation detectors;
Journal_Title :
Nuclear Science, IEEE Transactions on
DOI :
10.1109/TNS.1985.4333637