• DocumentCode
    876779
  • Title

    The Calibration of Microwave Attenuators by an Absolute Method

  • Author

    Laverick, Elizabeth

  • Volume
    5
  • Issue
    4
  • fYear
    1957
  • fDate
    10/1/1957 12:00:00 AM
  • Firstpage
    250
  • Lastpage
    254
  • Abstract
    A bridge method by means of which microwave attenuators can be calibrated absolutely is described, with a consideration of the main possible sources of error. A bridge was set up at lambda0 = 3.2 cm to test the principle of the method. It was shown that, using nonspecialized equipment, a high degree of accuracy was obtainable. An attenuator was calibrated over a range of 20 db, with an accuracy of the order of +-0.02 db. This accuracy is within the accuracy of other methods of calibration in current use, and there seems no reason why, with suitable precautions, the order of accuracy should not be improved still further, if required.
  • Keywords
    Attenuation; Attenuators; Bridges; Calibration; Detectors; Frequency; Microwave devices; Microwave theory and techniques; Phase detection; Phase shifters;
  • fLanguage
    English
  • Journal_Title
    Microwave Theory and Techniques, IRE Transactions on
  • Publisher
    ieee
  • ISSN
    0097-2002
  • Type

    jour

  • DOI
    10.1109/TMTT.1957.1125160
  • Filename
    1125160